With reference to: http://www.firstpr.com.au/rwi/dfish/tact-switches/ Raw results from force testing tact switches: milli-Newtons. Below that, displacement measurements. ALPS unsealed Switch Activation Hold 1 1280 600 2 1200 620 3 1220 630 4 1270 600 5 1240 610 6 1220 550 7 1250 550 8 1250 600 9 1220 640 10 1280 650 Average 1243 605 ALPS sealed Activation Hold 1 1570 1310 2 1620 1300 Average 1595 1305 Omron Sealed Switch Activation Hold 1 1500 810 2 1500 760 3 1470 700 4 1500 820 5 1480 800 6 1470 750 7 1480 720 8 1520 760 9 1460 760 10 1460 760 Average 1484 764 Switch type Activation Holding Delta Delta force force force ratio ALPS unsealed 1243 605 638 51.3% ALPS sealed 1595 1305 290 18.2% Omron sealed 1484 764 720 48.5% Displacement distances Each pixel in the zoomed-x2 images represents 0.0078125mm Using these files: ALPS-non-sealed-zoom-x2.png ALPS-sealed-zoom-x2.png Omron-sealed-zoom-x2.png I took measurements from: Up position to Active Force position. I call this the "Initial Displacement". Active Force position to Hold position, though it is labelled "Down" in the images. I call this the Click Displacement. Initial Click displacent, displacement using the active force position as the starting point and measuring to the down position pixels mm pixels mm ALPS unsealed 1 18 27 ALPS unsealed 2 20 32 Average 19 0.148mm 29.5 0.230mm ALPS sealed 17 0.123mm 16 0.125mm Omron sealed 1 19 30 Omron sealed 2 23 30 Average 21 0.164mm 30 0.234mm